PE-RT Underfloor Heating Kit 2 Port x 200m

Be the first to review this product

Availability: In stock

Excl. Tax: £367.78 Incl. Tax: £441.34

Quick Overview

Underfloor heating1 thermostatic blending valve with circulating pump are ideally suited to the temperature control of individual under floor heated rooms (max. 40m2)

PE-RT Underfloor Heating Kit 2 Port x 200m

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional electrical options for purchase with our kits. For other model stats or 12v networked stats please contact us.

  •    
  •    
  •    
  •    
  •    
  •    
  •    
  •    
  •    
  •    
Excl. Tax: £367.78 Incl. Tax: £441.34

Details

2 port kit provides temperature control of underfloor heating circuit using thermostatic blending valve with circulating pump. The heated floor area should not be greater than 40m2.

Set includes:

  • 2 Port Chrome Manifold
  • 22mm blending valve
  • 15-50 circulating pump
  • Flow and return temperature sensor and gauge
  • 2 x air vents
  • 2 x filling and drain points
  • 2 x 1" 1/4 turn manifold isolating valves
  • 50m of edge insulation
  • 2m of pipe conduit
  • 400 staples (to fix pipe to floor insulation)
  • 200m x 16mm PE-RT barrier pipe ~enough for enough for 40m2 @ 200mm pipe centres or
  • 30m2 @ 150mm pipe centres or
  • 20m2 @ 100mm pipe centres
  • brass pump and compression 22mm pipe unions
  • Instructions

Please note for clarity not all the parts supplied with this kit are shown in photo.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Questions on PE-RT Underfloor Heating Kit 2 Port x 200m

Sort by Descending
  • From max at 17/04/2011 12:51
    • can i use a normal sand and cement 50mm screed for the wet underfloor heating on top of insulation?
    • The mimimum screed depth required is 65mm, 75mm is recommended.
    • Do you find this question helpful?  Yes   No
  • From max at 17/04/2011 12:56
    • on top of insulation and wet underfoor heating can i use a normal 50mm sand and cement screed? Can the heating system be run of an lpg boiler and solar? What is the power requirement of the circulating pump?
    • The UFH system can be run off of an LPG boiler. The mimimum screed depth required is 65mm.
    • Do you find this question helpful?  Yes   No
  • From Nick at 31/07/2011 08:54
    • Would I need 1 or 2 thermostats to be added to an order for this product?
    • If you want to control it as 1 zone, you would have 1 stat.
      You can control it with 2 x stats if you want to control 2 areas
      differently, but then you would also need a Danfoss wiring centre.
    • Do you find this question helpful?  Yes   No
  • From Alan at 09/08/2011 10:51
    • Is this suitable for use with a combi-boiler with an integrated pump inside the boiler casing i.e. there is no way of taking a feed off the boiler to the UFH before the existing central heating pump (which is a Grunndfos Alpha).
    • It can be used with a combi boiler. If you have rads and UFH you would zone the 2 sections with 2 x 2 port zone valves to seperate them.
    • Do you find this question helpful?  Yes   No
  • From Paul at 25/10/2011 21:53
    • I want to install Underfloor heating in a new extension with two rooms. One room is 15m2 the other is only half that. The first room is a living room the second a utility room. I assume I will require a 2 Port 100m kit, but what else will I need to fully install this solution.
    • You would need a 2 port 150m. If you wanted to have 2 x zones you would also need 2 x actuators, 1 x Danfoss wiring centre and 2 x PRT room stats. If 1 x zone you would only need 1 x PRT stat and 1 x Honeywell junction box.
    • Do you find this question helpful?  Yes   No